KINGTEC 858
Kingtec MK858/MK858E series units are designed for frozen and fresh applications on the 20~50m3 mini refrigeration trucks.The road compressor is powered by the vehicle engine.While the unit with a second compressor it is powered by an electric motor. The stand-by unit is installed on the skirt of the truck.

KINGTEC MK858
EVK1600 evaporator

REFRIGERATION CAPACITY

30°C(86°F) ambient temperature
ATP Standard
100°F(38°C) ambient temperature
US-Standard
MK858 (R404A) MK858 (R404A)
Air return/on the road Watts BTU/hr Air return/on the road Watts BTU/hr
0°C(32°F) 8150 27800 2°C(35°F) 7900 27040
-20°C(-4°F) 4520 15400 -18°C(0°F) 4300 14660
50Hz electrical stand-by operation 60Hz electrical stand-by operation
0°C(32°F) 6500 22165 2°C(35°F) 6250 21320
-20°C(-4°F) 3320 11320 -18°C(0°F) 3160 10775

KINGTEC MK858 SYSTEM COMPONENTS

  • Condenser assembly
  • Evaporator assembly
  • Swash plate road compressor (With magnetic clutch)
  • Incab control box and wiring harness
  • Optional heating funtion:(Hot gas heating system or engine water heating
    system)

REFRIGERENT (CHLORINE ZERO)

MK-858 (R404A): HFC R404A 4.5kg

KINGTEC MK658 Stand-by Assembly

Stand-by assembly

ROAD COMPRESSOR (ENGINE DRIVEN)

  • Swash plate road compressor / 6cylinder
  • Displacement: (MK658)215cc / (MK858)313cc
  • Max recommended speed:3000rpm
  • Includes oil return separator

AIRFLOW VOLUME

EVK1600 evaporator: 39000m3/h (2300 cu ft/min)

KINGTEC MK358 Compressor

Compressor

ELECTRICAL SPECIFICATION

  • DC voltage options: DC12V or DC24V
  • Total current consumption on the road (Road compressor)
KINGTEC MK358 LAE Control Panel

LAE Control Panel

DC12V DC24V
MK-658 49A
  • Total stand-by current consumption
MK-858
230V/3Phase/50Hz  18.4A
400V/3Phase/50Hz  10.6A
415V/3Phase/50Hz  10.2A
230V/3Phase/60Hz 21.8A
240V/3Phase/60Hz 21.0A
460V/3Phase/60Hz 11A

WEIGHTS (APPROXIMATE)

  • MK-858 Condenser: 80kg/176Lb
  • MK-858 electrical stand-by assembly: 90kg/198Lb
  • EVK1600 Evaporator: 60kg/132Lb