KINGTEC S533

The KINGTEC S393 / S393E Transport Refrigeration Units

Kingtec S393 / S533 series units are designed for frozen and fresh applications on the 15~31m3 mini refrigeration trucks.The road compressor is powered by the vehicle engine. While the unit with a second compressor it is powered by an electric motor. The stand-by unit is installed on the skirt of the truck.

KINGTEC S533
EVK400 evaporator

REFRIGERATION CAPACITY

30°C(86°F) ambient temperature
ATP Standard
100°F(38°C) ambient temperature
US-Standard
S393 (R404A) S393 (R404A)
Air return/on the road Watts BTU/hr Air return/on the road Watts BTU/hr
0°C(32°F) 4430 15100 2°C(35°F) 4050 13800
-20°C(-4°F) 2220 7575 -18°C(0°F) 2030 6900
50Hz electrical stand-by operation 60Hz electrical stand-by operation
0°C(32°F) 3420 11670 2°C(35°F) 3550 12100
-20°C(-4°F) 1850 6310 -18°C(0°F) 1900 6480

KINGTEC S393 SYSTEM COMPONENTS

  • Condenser assembly
  • Evaporator assembly
  • Swash plate road compressor (With magnetic clutch)
  • Incab control box and wiring harness
  • Optional heating funtion:(Hot gas heating system or engine water heating
    system)
LAE Control Panel

LAE Control Panel

ROAD COMPRESSOR (ENGINE DRIVEN)

  • Swash plate road compressor
  • Displacement: 162cc
  • Max recommended speed: 3000rpm
  • Includes oil return separator

AIRFLOW VOLUME

EVK400 Evaporator 1650m3/h (970cu ft/min)

REFRIGERENT (CHLORINE ZERO)

  • S393 (R404a): HFC R404A 2.3kg

ELECTRICAL SPECIFICATION

  • DC voltage options: DC12V or DC24V
  • Total current consumption on the road (Road compressor)
DC12V DC24V
S393 48.4A 25.5A
  • Total stand-by current consumption
S393
230V/1Phase/50Hz 13.6a
230V/1Phase/60Hz 13.6a
230V/3Phase/50Hz 13.6a
230V/3Phase/60Hz 13.6a

WEIGHTS (APPROXIMATE)

  • S393 Condenser (with stand-by): 85(125)kg/187(276)Lb
  • EVK300C evaporator: 32kg/71Lb