The KINGTEC S393 / S393E Transport Refrigeration Units
Kingtec S393 / S533 series units are designed for frozen and fresh applications on the 15~31m3 mini refrigeration trucks.The road compressor is powered by the vehicle engine. While the unit with a second compressor it is powered by an electric motor. The stand-by unit is installed on the skirt of the truck.
REFRIGERATION CAPACITY |
|||||
30°C(86°F) ambient temperature
ATP Standard |
100°F(38°C) ambient temperature
US-Standard |
||||
S393 (R404A) | S393 (R404A) | ||||
Air return/on the road | Watts | BTU/hr | Air return/on the road | Watts | BTU/hr |
0°C(32°F) | 4430 | 15100 | 2°C(35°F) | 4050 | 13800 |
-20°C(-4°F) | 2220 | 7575 | -18°C(0°F) | 2030 | 6900 |
50Hz electrical stand-by operation | 60Hz electrical stand-by operation | ||||
0°C(32°F) | 3420 | 11670 | 2°C(35°F) | 3550 | 12100 |
-20°C(-4°F) | 1850 | 6310 | -18°C(0°F) | 1900 | 6480 |
KINGTEC S393 SYSTEM COMPONENTS
- Condenser assembly
- Evaporator assembly
- Swash plate road compressor (With magnetic clutch)
- Incab control box and wiring harness
- Optional heating funtion:(Hot gas heating system or engine water heating
system)
LAE Control Panel
ROAD COMPRESSOR (ENGINE DRIVEN)
- Swash plate road compressor
- Displacement: 162cc
- Max recommended speed: 3000rpm
- Includes oil return separator
AIRFLOW VOLUME
EVK400 Evaporator 1650m3/h (970cu ft/min)
REFRIGERENT (CHLORINE ZERO)
- S393 (R404a): HFC R404A 2.3kg
ELECTRICAL SPECIFICATION
- DC voltage options: DC12V or DC24V
- Total current consumption on the road (Road compressor)
DC12V | DC24V | |
S393 | 48.4A | 25.5A |
- Total stand-by current consumption
S393 | |
230V/1Phase/50Hz | 13.6a |
230V/1Phase/60Hz | 13.6a |
230V/3Phase/50Hz | 13.6a |
230V/3Phase/60Hz | 13.6a |
WEIGHTS (APPROXIMATE)
- S393 Condenser (with stand-by): 85(125)kg/187(276)Lb
- EVK300C evaporator: 32kg/71Lb